Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2015)

The data set contains the observation data of large aperture scintillator from January 1, 2015 to December 31, 2015. Two large aperture scintillation meters, bls450 and zzlas, are installed respectively. The site is located in donghuayuan Town, Huailai County, Hebei Province. The longitude and latitude of the observation point are 115.7880e, 40.3491n and 480m above sea level. The effective height of the large aperture scintillator is 14m, the optical path length is 1870m, the longitude and latitude of the transmitter are 115.8023e, 40.3596n, and the longitude and latitude of the receiver are 115.7825e and 40.3522n. The acquisition frequency of bls450 and zzlas is 5Hz and 1Hz respectively, with an average output of 1min. The original data of large aperture scintillator is 1 min, and the released data is 30 min average data after processing and quality control. The sensible heat flux is mainly obtained by iterative calculation based on Monin obkhov similarity theory and combined with automatic weather station data. In the process of iterative calculation, for bls450, the stability function of thiermann and Grassl, 1992 is selected; for zzlas, the stability function of Andreas, 1988 is selected. The main quality control steps include: (1) eliminating the data of cn2 saturation; (2) eliminating the data with weak demodulation signal intensity; (3) eliminating the data of precipitation time and one hour before and after; (4) eliminating the data of weak turbulence under stable conditions (U * less than 0.1m/s). Several explanations about the published data are as follows: (1) the Las data is mainly bls450, and the missing time is supplemented by zzlas observation, and the missing time is marked with - 6999. (2) Data header: date / time: date / time, cn2: structure parameter of air refraction index (m-2 / 3), H_ Las: sensible heat flux (w / m2). The meaning of data time, for example, 0:30 represents the average of 0:00-0:30; the data is stored in *. XLS format. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Haihe River Basin (Huailai station-automatic weather station-10m tower, 2014)

The dataset contains the observation data of the 10m tower automatic weather station on January 13, 2014 at solstice on December 31, 2014.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m. The automatic weather station is installed on a 10m tower, the acquisition frequency is 30s, and the output time is 10min.The observation factors include air temperature and relative humidity (5m), and the direction is due north.The wind speed (10m), the wind direction (10m), the direction is due to the north;Air pressure (installed in waterproof box);Rainfall (10m);The four-component radiation (5m), the direction is due to the south;The infrared surface temperature (5m), the arm is facing south, and the probe is facing vertically downward.The soil temperature and humidity probe was buried 1.5m south of the meteorological tower. The soil temperature probe was buried at a depth of 2cm, 4cm, 10cm, 20cm, 40cm, 80cm, 120cm and 160cm. The soil moisture sensor was buried at a depth of 2cm, 4cm, 10cm, 20cm, 80cm, 120cm and 160cm.The average soil temperature was buried 2,4 cm underground.Soil hot flow plates (3) are buried in the ground 6cm.Processing and quality control of observation data :(1) ensure 144 data per day (every 10min). If data is missing, it will be marked by -6999;(2) eliminate the moments with duplicate records;(3) data that is obviously beyond the physical meaning or the range of the instrument is deleted;(4) the format of date and time is unified, and the date and time are in the same column.For example, the time is: 2014-6-10-10:30.January 13 - March 26 due to probe problems, soil moisture data at a depth of 20cm was wrong;From January 21 to March 26, due to probe problems, soil moisture data at a depth of 120cm was wrong;From March 17 to March 26 due to probe problems, soil moisture data at depth of 2,4,10,20 cm were wrong.The soil heat flux G2 had a problem on June 16, BBB 0, July 9 due to the hot plate problem. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-10m tower, 2014)

The dataset contains the observation data of 10m tower vortex correlator on January 1, 2014, solstice, December 31, 2014.Station is located in huailai county, hebei province, east garden town, under the surface of irrigated corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The acquisition frequency of eddy correlation instrument is 10Hz, the frame height is 5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anemometer (Gill&CSAT3 (replaced on October 9, 2014) and the CO2/H2O analyzer (Li7500A) is 18cm (15cm after October 9). The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), Angle correction, frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.Data missing due to power converter damage. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-lysimeters, 2013)

The data set contains the observation data of the evapotranspiration apparatus on January 1, 2013 (solstice) and December 31, 2013.The site is located in huailai county, hebei province, east garden town, the underlying surface for corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m. The collection frequency of evapotranspiration permeameter is 1 time/minute, and the released data is the average of 10 minutes.The evapotranspiration meter is a cylindrical structure with a surface area of 1m2 and a buried depth of 1.5m. The observation accuracy of evapotranspiration is 0.01mm.Two evapotranspiration seeptometers were installed, one kept bare soil (lysimeter_1), the other for the corn underlay (lysimeter_2) during the growing season (May 10 - September 15).Soil temperature and humidity probe, soil water potential probe and soil heat flow plate are also installed in the evapotranspiration apparatus.The buried depth of the soil temperature sensor is 5cm, 30cm, 50cm, 100cm and 140cm.The buried depth of the soil water sensor is 2cm, 10cm, 20cm and 40cm.The soil heat flux plate is buried 10cm underground;The buried depth of the soil water potential sensor was 30cm and 140cm.Processing and quality control of observation data :(1) ensure 144 data per day (every 10min). If data is missing, it will be marked by -6999;(2) delete the data of observation anomalies caused during maintenance;(3) data that is obviously beyond the physical meaning or the range of the instrument is deleted;(4) the format of date and time is unified, and the date and time are in the same column.For example, the time is: 2013-6-10-10:30. The observation data released by the evapotranspiration permeameter include:Date/Time, weighing mass (i.l._1_wag_l_000 (Kg), i.l._2_wag_l_000 (Kg)), seepage mass (i.l._1_wag_d_000 (Kg), i.l._2_wag_d_000 (Kg)), soil heat flux (Gs_1_10cm, Gs_2_10cm) (W/m2),Multi-layer soil moisture (Ms_1_2cm, Ms_1_10cm, Ms_1_20cm, Ms_1_40cm, Ms_2_2cm, Ms_2_10cm, Ms_2_20cm, Ms_2_40cm) (%),Multi-layer soil temperature (Ts_1_5cm, Ts_1_30cm, Ts_1_50cm, Ts_1_100cm, Ts_1_140cm, Ts_2_140cm, ts_2_2_5cm, ts_2_2_50cm, Ts_2_100cm, Ts_2_140cm) (℃), soil water potential (TS_1_30 (hPa), TS_1_140 (hPa), TS_2_30 (hPa), TS_2_30 (hPa), TS_2_140 (hPa), TS_2_140 (hPa));The data is stored in *.xls format. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-40m tower, 2016)

The data set contains the observation data of 40m tower vortex correlator on January 1, 2016, solstice, 2016, December 31, 2016.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7923E, 40.3574N, and the altitude is 480m.The acquisition frequency of vortex correlativity instrument is 10Hz, the frame height is 3.5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anemometer (CSAT3) and the CO2/H2O analyzer (EC150) is 0cm. The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.There are many negative values of water vapor density measured by EC150 in winter, filled with -6999. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format.The data was missing during the period from May 26 to May 29 due to instrument calibration. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-automatic weather station-40m tower, 2017)

The data set contains observations from the 40m tower automatic weather station on January 1, 2017 at solstice on December 31, 2017.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7923E, 40.3574N, and the altitude is 480m. The automatic weather station is installed on a 40m tower with a collection frequency of 30s and an output of 10min.The observation factors include 7 layers of air temperature and relative humidity (3m, 5m, 10m, 15m, 20m, 30m, 40m), and the direction is due north.Wind speed on the 7th floor (3m, 5m, 10m, 15m, 20m, 30m, 40m), wind direction (10m), heading due north;Air pressure (installed in waterproof box);Rainfall (3m);Four-component radiation and photosynthetic effective radiation (4m), pointing due south;Infrared surface temperature (8m), the arm is facing south, the probe is facing vertically downward;The soil temperature and humidity probe was buried 1.5m south of the meteorological tower. The soil temperature probe was buried at a depth of 2cm, 4cm, 10cm, 20cm, 40cm, 80cm, 120cm and 160cm. The soil moisture sensor was buried at a depth of 2cm, 4cm, 10cm, 20cm, 80cm, 120cm and 160cm.The average soil temperature was buried 2,4 cm underground.Soil hot flow plates (3) are buried in the ground 6cm. Processing and quality control of observation data :(1) ensure 144 data per day (every 10min). If data is missing, it will be marked by -6999;(2) eliminate the moments with duplicate records;(3) data that is obviously beyond the physical meaning or the range of the instrument is deleted;(4) the format of date and time is unified, and the date and time are in the same column.For example, the time is: 2017-6-1010:30. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Haihe River Basin (Huailai station-large aperture scintillometer, 2017)

This data set contains the observation data of large aperture scintillator on January 7, 2017 at solstice on December 31, 2017. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, the underlying surface for corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. The original data of the large aperture scintillator is 1min, and the released data is the average data of 30min after processing and quality control. Among them, the sensible heat flux is mainly obtained by combining with the data of the automatic meteorological station and by iterative calculation based on the moning-obkhoff similarity theory.In the iterative calculation process, for BLS450, the stability function of Thiermann and Grassl, 1992 was selected.For zzlas, I'm going to pick Andreas 1988's stability function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-automatic weather station-10m tower, 2016)

The data set contains the observation data of 10m tower self-moving meteorological station on January 1, 2016, solstice, December 31, 2016.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m. The automatic weather station is installed on a 10m tower, the acquisition frequency is 30s, and the output time is 10min.The observation factors include air temperature and relative humidity (5m), and the direction is due north.The wind speed (10m), the wind direction (10m), the direction is due to the north;Air pressure (installed in waterproof box);Rainfall (10m);The four-component radiation (5m), the direction is due to the south;The infrared surface temperature (5m), the arm is facing south, and the probe is facing vertically downward.The soil temperature and humidity probe was buried at 1.5m to the south of the meteorological tower. The buried depth of the soil temperature probe was 0cm, 2cm, 4cm, 10cm, 20cm, 40cm, 80cm, 120cm and 160cm. The buried depth of the soil moisture sensor was 2cm, 4cm, 10cm, 10cm, 10cm, 10cm, 20cm, 80cm, 120cm and 160cm.The average soil temperature was buried 2,4 cm underground.Soil hot flow plates (3) are buried in the ground 6cm. Processing and quality control of observation data :(1) ensure 144 data per day (every 10min). If data is missing, it will be marked by -6999;(2) eliminate the moments with duplicate records;(3) data that is obviously beyond the physical meaning or the range of the instrument is deleted;(4) the format of date and time is unified, and the date and time are in the same column.For example, the time is: 2016-6-10-10:30.During January 1, solstice, April 15, there was a problem with the soil temperature sensor with a depth of 40cm, and the data was missing. Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2013)

This dataset contains the observation data of large aperture scintillator on January 1, 2013 (solstice) and December 31, 2013. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, under the surface of corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. Large aperture flicker meter raw data for 1 min, data released for 30 min after processing and quality control of the average data, including sensible heat flux is mainly combined with the automatic meteorological station data, based on similarity theory alonzo mourning - Mr. Hoff is obtained by iterative calculation, in the process of iterative calculation, for BLS450, select Thiermann and Grassl, the stability of the 1992 universal functions;For zzlas, select Andreas 1988's stability universal function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format Guo et al, 2020 is used for site introduction and Liu et al, 2013 for data processing

0 2020-10-28