Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2013)

This dataset contains the observation data of large aperture scintillator on January 1, 2013 (solstice) and December 31, 2013. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, under the surface of corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. Large aperture flicker meter raw data for 1 min, data released for 30 min after processing and quality control of the average data, including sensible heat flux is mainly combined with the automatic meteorological station data, based on similarity theory alonzo mourning - Mr. Hoff is obtained by iterative calculation, in the process of iterative calculation, for BLS450, select Thiermann and Grassl, the stability of the 1992 universal functions;For zzlas, select Andreas 1988's stability universal function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format Please refer to Yang guangchao et al. (2015) for observation test or site introduction, and refer to Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2014)

This data set contains the observation data of large aperture scintillator on January 1, 2014, solstice, December 31, 2014. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, under the surface of corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. Large aperture flicker meter raw data for 1 min, data released for 30 min after processing and quality control of the average data, including sensible heat flux is mainly combined with the automatic meteorological station data, based on similarity theory alonzo mourning - Mr. Hoff is obtained by iterative calculation, in the process of iterative calculation, for BLS450, select Thiermann and Grassl, the stability of the 1992 universal functions;For zzlas, select Andreas 1988's stability universal function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format Please refer to Yang guangchao et al. (2015) for observation test or site introduction, and refer to Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2015)

This data set contains the observation data of large aperture scintillator on January 1, 2015, solstice, December 31, 2015. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, the underlying surface for corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. The original data of the large aperture scintillator is 1min, and the released data is the average data of 30min after processing and quality control. Among them, the sensible heat flux is mainly obtained by combining with the data of the automatic meteorological station and by iterative calculation based on the moning-obkhoff similarity theory.In the iterative calculation process, for BLS450, the stability function of Thiermann and Grassl, 1992 was selected.For zzlas, I'm going to pick Andreas 1988's stability function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-large aperture scintillometer, 2016)

This data set contains the observation data of large aperture scintillator on January 1, 2016, solstice, December 31, 2016. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, under the surface of corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. The original data of the large aperture scintillator is 1min, and the released data is the average data of 30min after processing and quality control. Among them, the sensible heat flux is mainly obtained by combining with the data of the automatic meteorological station and by iterative calculation based on the moning-obkhoff similarity theory.In the iterative calculation process, for BLS450, the stability function of Thiermann and Grassl, 1992 was selected.For zzlas, I'm going to pick Andreas 1988's stability function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Haihe River Basin (Huailai station-large aperture scintillometer, 2017)

This data set contains the observation data of large aperture scintillator on January 7, 2017 at solstice on December 31, 2017. Two large aperture scintillator models BLS450 and zzlas were installed respectively.The site is located in huailai county, hebei province, east garden town, the underlying surface for corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The effective height of the large aperture scintillation instrument is 14m, the optical diameter length is 1870m, the longitude and latitude of the transmitting end is 115.8023e, 40.3596n, and the longitude and latitude of the receiving end is 115.7825e, 40.3522n.The acquisition frequencies of BLS450 and zzlas were 5Hz and 1Hz respectively, with an average output of 1min. The original data of the large aperture scintillator is 1min, and the released data is the average data of 30min after processing and quality control. Among them, the sensible heat flux is mainly obtained by combining with the data of the automatic meteorological station and by iterative calculation based on the moning-obkhoff similarity theory.In the iterative calculation process, for BLS450, the stability function of Thiermann and Grassl, 1992 was selected.For zzlas, I'm going to pick Andreas 1988's stability function.The main quality control steps include :(1) eliminating the data of Cn2 reaching saturation;(2) eliminate data with weak demodulation signal strength;(3) data of the time of precipitation and the hour before and after the precipitation are excluded;(4) data of weak turbulence under stable conditions were excluded (u* < 0.1m/s). Several notes on the released data :(1) LAS data is mainly BLS450, the missing time is supplemented by zzlas observation, and the missing time of both is marked by -6999.(2) data table: Date/Time: Date/Time, Cn2: air refractive index structure parameter (m-2/3), H_LAS: sensible heat flux (W/m2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-10m tower, 2014)

The dataset contains the observation data of 10m tower vortex correlator on January 1, 2014, solstice, December 31, 2014.Station is located in huailai county, hebei province, east garden town, under the surface of irrigated corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The acquisition frequency of eddy correlation instrument is 10Hz, the frame height is 5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anemometer (Gill&CSAT3 (replaced on October 9, 2014) and the CO2/H2O analyzer (Li7500A) is 18cm (15cm after October 9). The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), Angle correction, frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.Data missing due to power converter damage. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for observation test or site introduction, and refer to Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Haihe River Basin (Huailai station-eddy covariance system-10m tower, 2015)

The data set contains the observation data of the vorticity correlator of 10m tower on December 31, 2015 from January 1, 2015 to solstice.Station is located in huailai county, hebei province, east garden town, under the surface of irrigated corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The acquisition frequency of vortex correlativity instrument is 10Hz, the frame height is 5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anometer (CSAT3) and the CO2/H2O analyzer (Li7500A) is 15cm. The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.May 14 solstice May 20 and May 24 solstice June 6 due to power converter damage, data missing. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-10

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-10m tower, 2016)

The data set contains the observation data of 10m tower vortex correlator on January 1, 2016, solstice, 2016, December 31, 2016.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The acquisition frequency of vortex correlativity instrument is 10Hz, the frame height is 5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anometer (CSAT3) and the CO2/H2O analyzer (Li7500A) is 15cm. The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.On May 27, BBB 0, July 22, there was a problem with the ultrasonic anemometer, and the data was missing. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-09

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-10m tower, 2017)

The data set contains the observation data of 10m tower vortex correlator on January 1, 2017, solstice, 2017, December 31, 2017.Station is located in huailai county, hebei province, east garden town, under the surface of irrigated corn.The latitude and longitude of the observation point is 115.7880E, 40.3491N, and the altitude is 480m.The acquisition frequency of vortex correlativity instrument is 10Hz, the frame height is 5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anometer (CSAT3) and the CO2/H2O analyzer (Li7500A) is 15cm. The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.On May 27, BBB 0, July 22, there was a problem with the ultrasonic anemometer, and the data was missing. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-09

Multi-scale surface flux and meteorological elements observation dataset in the Hai River Basin (Huailai station-eddy covariance system-40m tower, 2016)

The data set contains the observation data of 40m tower vortex correlator on January 1, 2016, solstice, 2016, December 31, 2016.The station is located in east garden town, huailai county, hebei province.The latitude and longitude of the observation point is 115.7923E, 40.3574N, and the altitude is 480m.The acquisition frequency of vortex correlativity instrument is 10Hz, the frame height is 3.5m, the ultrasonic direction is due to the north, and the distance between the ultrasonic anemometer (CSAT3) and the CO2/H2O analyzer (EC150) is 0cm. The released data is the 30-minute data obtained from the post-processing of the original collected 10Hz data with Eddypro software. The main steps of the processing include: outfield value elimination, delay time correction, coordinate rotation (secondary coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction.Quality assessment for each intercompared to at the same time, mainly is the atmospheric stability (Δ st) and turbulent characteristics of similarity (ITC) test.The 30min pass value output after processing was also screened :(1) the data when the instrument was wrong was removed;(2) data of 1h before and after precipitation were excluded;(3) the missing rate of 10Hz original data is more than 10% every 30min;(4) the observed data of weak turbulence at night were excluded (u* less than 0.1m/s).The average period of observation data was 30 minutes, 48 data a day, and the missing data was marked as -6999.There are many negative values of water vapor density measured by EC150 in winter, filled with -6999. The observation data released by vortex correlator include:Date/Time for the Date/Time, wind Wdir (°), Wnd horizontal wind speed (m/s), standard deviation Std_Uy lateral wind speed (m/s), ultrasonic virtual temperature Tv (K), the water vapor density H2O (g/m3), carbon dioxide concentration CO2 (mg/m3), friction velocity Ustar) (m/s), the length of cloth hoff, sensible heat flux Hs (W/m2), latent heat flux LE (W/m2), carbon dioxide flux Fc (mg/(m2s)), the quality of the sensible heat flux identifier QA_Hs, the quality of the latent heat flux identifier QA_LE.The quality of the sensible heat and latent heat, carbon dioxide flux identification is divided into three (quality id 0: (Δ st < 30, the ITC < 30);1: (Δ st < 100, ITC < 100);The rest are 2).The meaning of data time, such as 0:30 represents the average between 0:00 and 0:30;The data is stored in *.xls format.The data was missing during the period from May 26 to May 29 due to instrument calibration. Please refer to Yang guangchao et al. (2015) for information of observation test or site, and Liu et al. (2013) for data processing.

0 2020-03-09